Prestressed metal bellows


1. Rigidity test: When the concentrated load is 0.75KN or the uniform load is 1.5KN, the radial deformation is less than 0.1d. 2, anti-seepage test: grouting or water-cement ratio of 0.5 cement slurry 30 minutes without water leakage, leakage. 3, tensile test: axial tension 5KN pipe wall without damage. 4. Pull-out test: embedded in concrete, the pull-out force is more than 2.3 times that of the anchor bolt design. 5, bending test: when the bending degree is 30d of the radius of curvature, there is no water leakage and leakage.

Category:


1. Rigidity test: When the concentrated load is 0.75KN or the uniform load is 1.5KN, the radial deformation is less than 0.1d.

2, anti-seepage test: grouting or water-cement ratio of 0.5 cement slurry 30 minutes without water leakage, leakage.

3, tensile test: axial tension 5KN pipe wall without damage.

4. Pull-out test: embedded in concrete, the pull-out force is more than 2.3 times that of the anchor bolt design.

5, bending test: when the bending degree is 30d of the radius of curvature, there is no water leakage and leakage.


Keywords:

Prestressed metal bellows

Previous:

Next:

Related Products

Message